公務(wù)員期刊網(wǎng) 精選范文 煙氣監(jiān)測(cè)范文

煙氣監(jiān)測(cè)精選(九篇)

前言:一篇好文章的誕生,需要你不斷地搜集資料、整理思路,本站小編為你收集了豐富的煙氣監(jiān)測(cè)主題范文,僅供參考,歡迎閱讀并收藏。

第1篇:煙氣監(jiān)測(cè)范文

Abstract: Through analyzing the mercury in flue gas online monitoring technology of cold vapor atomic absorption spectrometry, the article designs mercury in flue gas online monitoring instruments based on cold vapor atomic absorption spectrometry, including sampling units, test unit, control unit, and display unit. The instrument test data on the drift of zero point, span drift is ideal, realizing the real-time, secure, and stable monitoring of mercury in flue gas.

關(guān)鍵詞: 冷原子吸收光譜法;在線監(jiān)測(cè);監(jiān)測(cè)技術(shù)

Key words: cold vapor atomic absorption spectrometry;online monitoring;monitoring technology

中圖分類(lèi)號(hào):X82 文獻(xiàn)標(biāo)識(shí)碼:A 文章編號(hào):1006-4311(2012)35-0032-02

0 引言

伴隨著工業(yè)的發(fā)展,汞的用途越來(lái)越廣,生產(chǎn)量急劇增加,從而使大量的汞隨著人類(lèi)活動(dòng)而進(jìn)入環(huán)境。主要包括:施用含汞農(nóng)藥和含汞污泥肥料;汞礦的開(kāi)采、冶煉;含汞廢水灌溉;城市垃圾、廢物焚燒等等。人類(lèi)活動(dòng)造成水體汞污染,主要來(lái)自氯堿、塑料、電池、電子等工業(yè)排放的廢水。而排向大氣和土壤的也將隨著水循環(huán)回歸入水體。據(jù)第一財(cái)經(jīng)日?qǐng)?bào)綜合報(bào)道,專(zhuān)家介紹,汞被聯(lián)合國(guó)環(huán)境規(guī)劃署列為全球性污染物,是除了溫室氣體外唯一一種對(duì)全球范圍產(chǎn)生影響的化學(xué)物質(zhì)。

1 煙氣中汞在線監(jiān)測(cè)儀器原理

煙氣做采樣泵的作用下經(jīng)過(guò)氣路切換單元(除濕、除塵和除硫),通過(guò)隔膜泵將汞蒸氣輸送到檢測(cè)池中,汞蒸氣在254nm下有強(qiáng)烈吸收,汞蒸氣的濃度與吸收強(qiáng)度成正比,原理是朗伯-比爾定律

I=I0e-KCL

式中:I為吸收后的光強(qiáng)度;I0是物質(zhì)濃度為零(即不存在吸收物質(zhì))時(shí)的光強(qiáng)度;C為物質(zhì)濃度;L為比色皿(采樣槽)的長(zhǎng)度;K為吸收常數(shù)。對(duì)于一個(gè)特定的采樣槽,其長(zhǎng)度L不變;對(duì)于特定的測(cè)量波長(zhǎng)以及特定的被測(cè)物,吸收常數(shù)K基本不變,因此通過(guò)測(cè)量吸收前后的可見(jiàn)光的強(qiáng)度,便可以測(cè)量出煙氣中汞的濃度。

2 煙氣中汞在線監(jiān)測(cè)儀器設(shè)計(jì)

2.1 儀器結(jié)構(gòu)框圖 儀器結(jié)構(gòu)框圖如圖1所示。

圖1所示,監(jiān)測(cè)儀器由三個(gè)單元組成,分別為氣路切換單元、檢測(cè)單元和顯示單元,氣路切換單元主要完成煙氣和零氣的切換處理,并針對(duì)不同的通道進(jìn)行不同的預(yù)處理,其中煙氣通道進(jìn)行除塵和超濾處理,以減少對(duì)汞檢測(cè)的影響。檢測(cè)單元由光源、檢測(cè)池和光電探測(cè)器組成,主要完成汞蒸氣的吸收光信號(hào)檢測(cè),顯示單元由數(shù)據(jù)計(jì)算、數(shù)據(jù)顯示和數(shù)據(jù)輸出組成,主要完成對(duì)檢測(cè)到信號(hào)進(jìn)行處理,經(jīng)過(guò)運(yùn)算得到吸光度,然后代入內(nèi)置工作曲線進(jìn)行計(jì)算得到汞濃度,最后將濃度結(jié)果通過(guò)RS485或4-20mA輸出。

2.2 氣路切換單元設(shè)計(jì)

2.2.1 切換器 切換器由三通切換閥和驅(qū)動(dòng)器組成,當(dāng)進(jìn)行正常測(cè)試時(shí),切換器切換到煙氣通道,煙氣經(jīng)由除塵器和超濾器進(jìn)入檢測(cè)單元,當(dāng)儀器需要進(jìn)行零點(diǎn)校準(zhǔn)時(shí),切換器切換到零氣通道,零氣經(jīng)由零氣通道直接進(jìn)入檢測(cè)單元。切換閥采用低壓24V控制模式,當(dāng)三通電磁閥有電時(shí),切換閥打開(kāi),失電時(shí),切換閥關(guān)閉;當(dāng)控制電源故障失電時(shí),切換閥關(guān)閉。驅(qū)動(dòng)器用于驅(qū)動(dòng)三通電磁閥,能通過(guò)接收TTL控制信號(hào)是否產(chǎn)生24V電壓。

2.2.2 除塵器 除塵器采用不銹鋼材料制成的圓柱形多孔濾芯,煙氣通過(guò)入口進(jìn)入濾芯,煙氣中的灰塵在濾芯上被攔截下來(lái),煙氣得到凈化,當(dāng)濾芯被附著的灰塵累積到一定程度后,啟動(dòng)反清洗裝置,高壓空氣通過(guò)反清洗入口對(duì)濾芯進(jìn)行高壓反清洗,附著在濾芯表面的灰塵被脫落,達(dá)到濾芯自動(dòng)清潔的目的。

2.2.3 超濾器 采用歐洲優(yōu)質(zhì)過(guò)濾材料和不銹鋼骨架,具有過(guò)濾效率高、耐腐蝕、強(qiáng)度高、氣流阻力低、使用壽命長(zhǎng)等特點(diǎn)。濾芯最外層采用抗油、耐酸類(lèi)化學(xué)腐蝕的疏水性泡沫套筒,防止了聚結(jié)液體重新進(jìn)入氣流,確保了高效率除有機(jī)干擾物,以減少有機(jī)物對(duì)汞檢測(cè)造成的影響。

2.3 檢測(cè)單元設(shè)計(jì)

2.3.1 光源 監(jiān)測(cè)儀采用低壓汞燈作為光源,汞燈是指汞蒸氣壓力為1.3~13Pa(0.01~0.1mmHg),主要發(fā)射波長(zhǎng)在紫外區(qū)的253.7nm(0.01mmHg),相當(dāng)能量為471.0kJ/mol(112.5kcal/mol),占燈的總能量的70%的汞蒸氣弧光燈。25℃時(shí),該燈的主射線為253.7和184.9nm。低壓汞燈光強(qiáng)低,光固化速度慢,但發(fā)熱量小,不需冷卻就可使用。由于汞燈發(fā)出的光時(shí)發(fā)散的,使用的時(shí)候需要使用透鏡將光聚焦,提高汞燈穿過(guò)檢測(cè)池的能量。

2.3.2 檢測(cè)池 在光譜吸收式氣體檢測(cè)系統(tǒng)中,氣室的有效吸收光程是決定系統(tǒng)檢測(cè)靈敏度的關(guān)鍵參數(shù)之一,本儀器采用懷特型氣室的方法進(jìn)行設(shè)計(jì)。本長(zhǎng)光程氣室內(nèi)壁以及氣室反射鏡片均要求較高的反射率,以避免多次反射后造成的光強(qiáng)損失,氣室內(nèi)壁及反射鏡片采用高反射率的金作為鍍層,使光強(qiáng)反射率達(dá)到95%以上。氣室的入射及出射窗口要求對(duì)于目標(biāo)波長(zhǎng)的光具有較高的透射率,根據(jù)波長(zhǎng)的不同窗口使用的材料也會(huì)有所不同,光透射率達(dá)到92%以上。光路長(zhǎng)度與測(cè)量精度有關(guān),對(duì)于低濃度氣體測(cè)量,光路達(dá)到8米以上。氣室具有較強(qiáng)的耐腐蝕性,對(duì)于腐蝕性氣體(如HCL、HF等)具有良好的耐腐蝕性,尤其是樣氣的出入口部分,鍍層起到足夠的保護(hù)作用。

2.3.3 光電探測(cè)器 光電探測(cè)器的工作原理是基于光電效應(yīng),熱探測(cè)器基于材料吸收了光輻射能量后溫度升高,從而改變了它的電學(xué)性能,它區(qū)別于光子探測(cè)器的最大特點(diǎn)是對(duì)光輻射的波長(zhǎng)無(wú)選擇性。在光電探測(cè)器的前端設(shè)置了253.7nm的濾光片,可以將其他波長(zhǎng)的光攔截。

2.3.4 信號(hào)放大與AD轉(zhuǎn)化 這部分主要是將光電探測(cè)器探測(cè)到的光信號(hào)進(jìn)行放大,使其達(dá)到AD轉(zhuǎn)化前的信號(hào)強(qiáng)度要求,AD轉(zhuǎn)化電路完成信號(hào)的數(shù)字化。

2.3.5 數(shù)據(jù)采集處理 數(shù)據(jù)采集處理部分主要是完成光電探測(cè)器后端的信號(hào)進(jìn)行采集并處理,使其采集到的信號(hào)更加有代表性。數(shù)據(jù)處理采用算術(shù)平均濾波法,提高其有用信號(hào)的比重,消除變化信號(hào)中的尖脈沖干擾值。

2.3.6 檢測(cè)單元系統(tǒng)結(jié)構(gòu) 檢測(cè)單元系統(tǒng)結(jié)構(gòu)如圖2所示。光源由低壓汞燈構(gòu)成,在檢測(cè)池的光路入口和出口分別設(shè)置了聚焦透鏡,光源發(fā)出的光透過(guò)聚焦透鏡進(jìn)入檢測(cè)池,穿過(guò)聚焦透鏡,進(jìn)入光電探測(cè)器。

2.4 顯示單元

2.4.1 顯示單元結(jié)構(gòu) 顯示單元以嵌入式低功耗CPU為核心(ARM CPU,主頻400MHz)的高性能嵌入式一體化觸摸屏工控機(jī),設(shè)計(jì)采用了7英寸高亮度TFT液晶顯示屏(分辨率800×480),四線電阻式觸摸屏(分辨率1024×1024),內(nèi)置128M FLASH,24VDC供電,采用wince6.0操作系統(tǒng),工控機(jī)的系統(tǒng)結(jié)構(gòu)圖見(jiàn)圖3。

2.4.2 數(shù)值運(yùn)算 儀器具有校準(zhǔn)功能,能根據(jù)不同濃度的汞標(biāo)氣記錄吸光強(qiáng)度值,然后采用乘二法進(jìn)行線性擬合,得到線性方程,并將線性方程系數(shù)保存在儀器存儲(chǔ)器中,然后將數(shù)據(jù)顯示在顯示屏上,并將數(shù)據(jù)保存到工控機(jī)內(nèi)部存儲(chǔ)器中。儀器設(shè)置了4-20mA模擬輸出和RS485數(shù)字輸出功能,可以提供外部?jī)x器或數(shù)采儀進(jìn)行數(shù)據(jù)采集。

3 性能測(cè)試

為了研究研制的在線監(jiān)測(cè)技術(shù)定量分析過(guò)程中存在的系統(tǒng)誤差和偶然誤差,本文設(shè)計(jì)了專(zhuān)門(mén)的零點(diǎn)漂移、量程漂移和跨度漂移實(shí)驗(yàn),本儀器的測(cè)量量程為0-100μg/m3。零點(diǎn)漂移是讓監(jiān)測(cè)儀每隔1h測(cè)試零氣,連續(xù)監(jiān)測(cè)24h,計(jì)算相對(duì)于監(jiān)測(cè)儀的最小讀數(shù),儀器指示值在一定時(shí)間內(nèi)的變化;量程漂移是讓監(jiān)測(cè)儀每隔2h測(cè)試80μg/m3汞標(biāo)氣,連續(xù)監(jiān)測(cè)24h,計(jì)算相對(duì)于自動(dòng)分析儀的測(cè)定量程,儀器指示值在一定范圍內(nèi)的變化大?。豢缍绕剖亲尡O(jiān)測(cè)儀每隔1天測(cè)試50μg/m3汞標(biāo)氣,連續(xù)監(jiān)測(cè)1周,計(jì)算相對(duì)于自動(dòng)分析儀的測(cè)定量程,儀器指示值在一定范圍內(nèi)的變化大小。

表1是性能測(cè)試結(jié)果,可以看到,零點(diǎn)漂移值為1.37%,量程漂移值為0.067%,跨度漂移值為0.05%,性能指標(biāo)比較理想。

4 結(jié)論

通過(guò)設(shè)計(jì)氣路切換單元、檢測(cè)單元和顯示單元,成功研制了煙氣汞在線監(jiān)測(cè)儀器,能應(yīng)用于煙氣中汞的在線實(shí)時(shí)監(jiān)測(cè),具有實(shí)時(shí)、快速、安全和可靠等特點(diǎn),具備了良好的市場(chǎng)推廣前景。

參考文獻(xiàn):

[1]李冬梅.燃煤鍋爐煙氣汞污染控制技術(shù)淺析[J].環(huán)境保護(hù)與循環(huán)經(jīng)濟(jì),2011.

第2篇:煙氣監(jiān)測(cè)范文

關(guān)鍵詞 煙氣監(jiān)測(cè) 故障 分析 處理

1電廠煙氣監(jiān)測(cè)系統(tǒng)簡(jiǎn)介

煙氣污染物在線監(jiān)測(cè)系統(tǒng)(CEMS)是實(shí)時(shí)、連續(xù)監(jiān)測(cè)污染物參數(shù)的系統(tǒng),主要監(jiān)測(cè)煙氣中的顆粒物濃度、氣態(tài)污染物濃度(SO2、NOx、O2)、輔助參數(shù)(煙氣溫度、流速、氧量、濕度、壓力)等。完整的CEMS包括氣態(tài)污染物監(jiān)測(cè)子系統(tǒng)、煙氣排放參數(shù)監(jiān)測(cè)子系統(tǒng)、顆粒物監(jiān)測(cè)子系統(tǒng)、系統(tǒng)控制及數(shù)據(jù)采集處理子系統(tǒng)等輔助設(shè)施子系統(tǒng)。

某電廠共5臺(tái)燃煤發(fā)電機(jī)組,其中1~3號(hào)機(jī)組容量各為200MW,4、5號(hào)機(jī)組容量300MW。5臺(tái)機(jī)組的煙氣脫硫裝置均采用石灰石-石膏濕法工藝,其中1~4號(hào)脫硫裝置由浙江浙大網(wǎng)新公司提供,5號(hào)脫硫裝置由上海常凈公司提供。5套脫硫裝置均為1爐1塔配置。機(jī)組煙氣經(jīng)脫硫處理后,由二條210米高煙囪排放。排放口處安裝有北京雪迪龍自動(dòng)控制系統(tǒng)有限公司生產(chǎn)的SIEMENS 7-200型煙氣排放連續(xù)監(jiān)測(cè)系統(tǒng)(CEMS)。顆粒物粉塵監(jiān)測(cè)選用RBV-2030型光學(xué)法煙塵監(jiān)測(cè)儀。

CEMS系統(tǒng)采用北京雪迪龍自動(dòng)控制系統(tǒng)有限公司SCS -900系統(tǒng)配置(圖1)。

圖1 CEMS系統(tǒng)圖

2 常見(jiàn)故障及處理

2.1 樣氣流量偏低

煙道中的樣氣經(jīng)過(guò)采樣探頭和電加熱伴熱管由取樣泵抽取至分析儀表柜。樣氣的過(guò)濾主要由探頭過(guò)濾器來(lái)完成,過(guò)濾器中的濾芯為2μm 孔隙的碳化硅陶瓷材料,含塵氣體經(jīng)過(guò)濾芯,粉塵被過(guò)濾下來(lái),雖然有自動(dòng)反吹系統(tǒng)定時(shí)進(jìn)行反吹,但因過(guò)濾器長(zhǎng)期被加熱至120 ℃及以上運(yùn)行,不可避免出現(xiàn)堵塞和高溫老化。如反吹壓縮空氣偶爾帶有水汽會(huì)造成樣氣降溫結(jié)露并產(chǎn)生少量液態(tài)酸水,容易與采樣管中粉塵粘合并粘在采樣探管內(nèi)壁上,長(zhǎng)時(shí)間不清理就會(huì)影響樣氣流量。可以在CEMS 系統(tǒng)停運(yùn)期間,將采樣管拆下清理內(nèi)部雜物并檢查采樣探管的腐蝕情況。為保證煙氣流量,過(guò)濾器濾芯每半年應(yīng)更換一次,定時(shí)檢查正常與否。反吹壓縮空氣管路應(yīng)加裝自動(dòng)疏水裝置。

經(jīng)過(guò)冷凝器的樣氣仍可能有一部分殘余水汽沒(méi)能去除,并夾雜著少量粉塵顆粒進(jìn)入到保護(hù)過(guò)濾器中,長(zhǎng)時(shí)間運(yùn)行后會(huì)污堵過(guò)濾器和流量計(jì),使進(jìn)入分析儀的樣氣流量下降,造成流量報(bào)警而停運(yùn)采樣泵。因此,要定期檢查保護(hù)過(guò)濾器,如果表面顏色發(fā)黃 (正常為白色) 應(yīng)及時(shí)更換。保護(hù)過(guò)濾器表面結(jié)露時(shí)還應(yīng)及時(shí)吹掃采樣管道,流量計(jì)中如掛有水汽應(yīng)及時(shí)將機(jī)柜內(nèi)的樣氣管路拆下沖洗烘干,以避免這些水汽進(jìn)到檢測(cè)池造成酸性腐蝕。

此外,當(dāng)發(fā)現(xiàn)流量偏低并伴隨流量計(jì)轉(zhuǎn)子波動(dòng)時(shí),排除取樣泵故障前提下,檢查系統(tǒng)排氣是否正常。

2.2 樣氣帶水

為保證樣氣在傳輸過(guò)程中不出現(xiàn)冷凝現(xiàn)象,避免氣體成分損失及樣氣管路腐蝕,采用直接抽取加熱法的取樣探頭及取樣管線均采用120 ℃~140 ℃高溫加熱。樣氣進(jìn)入分析柜后,通過(guò)冷凝器對(duì)樣氣進(jìn)行快速冷凝,經(jīng)過(guò)致冷后的樣氣再經(jīng)過(guò)保護(hù)過(guò)濾器過(guò)濾最后進(jìn)入分析儀分析。樣氣帶水是直接抽取加熱法測(cè)量系統(tǒng)最常見(jiàn)的故障,原因有:

(1) 取樣探頭及伴熱管的加熱由探頭溫控器及取樣管溫控器控制,溫控器的觸點(diǎn)經(jīng)常性地關(guān)斷和吸合,會(huì)造成觸點(diǎn)接觸不良,即便溫控器溫度設(shè)定在正常范圍,但電加熱并未真正工作,造成樣氣在取樣管線冷凝帶水。應(yīng)經(jīng)常檢查取樣管線溫度是否在設(shè)定范圍,改變溫控器溫度設(shè)定值,觀察觸點(diǎn)切換是否正常。

(2) 煙氣中的水汽冷凝成液滴后由蠕動(dòng)泵排出。泵管長(zhǎng)時(shí)間運(yùn)行后膠管極易老化變形,致水汽無(wú)法及時(shí)排出。應(yīng)經(jīng)常檢查蠕動(dòng)泵是否停轉(zhuǎn),尤其要檢查蠕動(dòng)泵泵管,如泵管變形應(yīng)及時(shí)更換,更換泵管時(shí)要注意把泵管卡到位。

(3)通過(guò)測(cè)量伴熱管電阻可以評(píng)估伴熱管性能,方法為:假設(shè)伴熱管長(zhǎng)50米,查設(shè)備資料得伴熱采樣管線功率為a瓦/米,則該伴熱管理論功率為50a瓦。實(shí)測(cè)伴熱采樣管線功率為b歐姆,由公式P=U2/R得48400/b≈50a ,若偏差較遠(yuǎn)可適時(shí)更換該伴熱管。

2.3 煙氣參數(shù)失真

煙氣測(cè)量參數(shù)(S02、NOx、02)、含塵量數(shù)據(jù)的失真既影響脫硫系統(tǒng)工藝控制,也影響環(huán)保對(duì)電廠排放的考核。影響測(cè)量結(jié)果準(zhǔn)確性的原因主要有以下幾方面:

(1) 煙氣由取樣泵從煙道內(nèi)抽取至分析儀表,取樣管線存在泄漏勢(shì)必造成空氣混入樣氣中,從而使煙氣中參數(shù)S02 偏低,02 偏高。管線泄漏分為加熱管線泄露和機(jī)柜內(nèi)預(yù)處理系統(tǒng)泄露兩種。區(qū)別方法為于分水器處斷開(kāi)管線連接,用手堵死采樣口,在取樣泵的作用下,如果機(jī)柜內(nèi)預(yù)處理系統(tǒng)無(wú)泄露,則正常情況流量計(jì)內(nèi)轉(zhuǎn)子應(yīng)慢慢下降然后在流量計(jì)下半部分跳動(dòng)。之后對(duì)應(yīng)檢查管路中的接頭、脹圈是否緊固,電磁閥是否密封。特別是探頭吹掃電磁閥和校零電磁閥由于需定時(shí)進(jìn)行切換吹掃和校零,閥門(mén)滑桿擋頭磨損和空氣中污物進(jìn)入會(huì)影響電磁閥密封性,應(yīng)經(jīng)常進(jìn)行檢查和清理。更換探頭過(guò)濾器時(shí)要檢查密封墊,并同時(shí)更換手柄塞上的O型圈。

(2)CEMS零位是通過(guò)標(biāo)定空氣校準(zhǔn)的??諝馊庸軕?yīng)遠(yuǎn)離污染氣體,避免零位偏移造成煙氣參數(shù)異常。選擇標(biāo)氣時(shí)應(yīng)盡量選擇實(shí)際測(cè)量值處于標(biāo)氣量程附近的標(biāo)氣。

(3) 煙塵儀光學(xué)窗口鏡片極易被煙道中的粉塵及油汽附著而降低其透光性造成監(jiān)測(cè)數(shù)據(jù)增大。因此運(yùn)行中要定期檢查光學(xué)窗口是否被污染,清潔光學(xué)窗口需用50 %的化學(xué)純級(jí)的酒精和蒸餾水的混合溶液。如光學(xué)窗口表面經(jīng)常短時(shí)間內(nèi)積灰應(yīng)檢查清潔風(fēng)系統(tǒng)有無(wú)臟堵現(xiàn)象,風(fēng)機(jī)是否運(yùn)轉(zhuǎn)正常,保證灰塵不進(jìn)入光學(xué)頭。

3 其他注意事項(xiàng)

(1) 嚴(yán)禁在不安裝探頭過(guò)濾器的情況下使用取樣探頭,否則將會(huì)導(dǎo)致探頭及采樣管線的嚴(yán)重堵塞。更換探頭過(guò)濾器時(shí)要切斷樣氣和電源,并使用防護(hù)手套,防止?fàn)C傷。

(2) O2 傳感器的測(cè)量電壓因老化會(huì)逐漸降低,經(jīng)常檢查其測(cè)量電壓,當(dāng)< 6mV 時(shí)應(yīng)及時(shí)更換O2傳感器,防止因O2 電勢(shì)過(guò)低造成系統(tǒng)故障無(wú)法進(jìn)行測(cè)量。O2傳感器中含有醋酸,會(huì)燒壞無(wú)防護(hù)的皮膚,所以在替換O2傳感器時(shí),不可以損壞它的外殼。老化或有故障的廢O2傳感器為有毒廢棄物,必須封裝好送倉(cāng)庫(kù)回收統(tǒng)一處理

(3) 清理煙塵儀光學(xué)窗口鏡片時(shí)應(yīng)確認(rèn)光學(xué)頭已斷電,所使用溶液應(yīng)不含油分,如用含有油分的酒精溶液清潔光學(xué)窗口,當(dāng)酒精揮發(fā)后在鏡片表面會(huì)有殘留的油分,影響測(cè)量準(zhǔn)確性。

(4) 煙氣分析系統(tǒng)通常放置在監(jiān)測(cè)小屋內(nèi),應(yīng)保持屋內(nèi)的環(huán)境衛(wèi)生,保持CEMS 小屋的溫度在20 ℃左右,注意空調(diào)和通風(fēng)是否正常,如果房間內(nèi)溫度過(guò)高或過(guò)低,不僅會(huì)對(duì)數(shù)據(jù)準(zhǔn)確性產(chǎn)生影響,而且會(huì)造成設(shè)備故障,影響設(shè)備的使用壽命。

(5) 經(jīng)常檢查收集水箱內(nèi)積水情況,并及時(shí)清理,防止廢液溢出,污染CEMS 小屋。

4 結(jié)語(yǔ)

第3篇:煙氣監(jiān)測(cè)范文

關(guān)鍵詞CEMS;脫硫;連續(xù)監(jiān)測(cè);SO2

中圖分類(lèi)號(hào):TN931.3 文獻(xiàn)標(biāo)識(shí)碼:A

我廠一期2×330MW脫硫于2008年底投產(chǎn),采用石灰石-石膏干法脫硫工藝,無(wú)煙氣旁路,煙氣連續(xù)檢測(cè)系統(tǒng)采用的是北京雪迪龍公司的SCS-900型系統(tǒng),測(cè)量采用直接抽取法。

1 我廠脫硫CEMS煙氣在線監(jiān)測(cè)系統(tǒng)概述

脫硫在線監(jiān)測(cè)系統(tǒng)測(cè)量的主要參數(shù):SO2、NOX、O2、流量、煙塵、溫度、壓力等,其中SO2、NOX采用NRIR不分光紅外法、O2采用電化學(xué)法用分析儀檢測(cè),粉塵濃度(激光后散射法)、流量(皮托管差壓法)、溫度、壓力等通過(guò)安裝在現(xiàn)場(chǎng)平臺(tái)上的儀表進(jìn)行檢測(cè),這些數(shù)據(jù)經(jīng)過(guò)信號(hào)處理傳至PLC,上位機(jī)與PLC進(jìn)行通訊(RS485)采集到環(huán)保要求數(shù)據(jù)。通過(guò)DAS站對(duì)環(huán)保數(shù)據(jù)進(jìn)行存儲(chǔ)、打印、統(tǒng)計(jì)和傳輸,并分別傳至DCS和環(huán)保局。

2 系統(tǒng)原理

2.1 系統(tǒng)原理

CEMS煙氣連續(xù)排放監(jiān)測(cè)系統(tǒng)(Continuous emission monitoring systems for flue gas) 簡(jiǎn)稱(chēng)CEMS,主要用來(lái)連續(xù)監(jiān)測(cè)煙氣中煙塵及二氧化硫及氮氧化物的排放濃度及排放總量。系統(tǒng)主要包括:煙氣顆粒物監(jiān)測(cè)子系統(tǒng)(煙塵CEMS)、氣態(tài)污染物監(jiān)測(cè)子系統(tǒng)(煙塵CEMS)、氣態(tài)污染物監(jiān)測(cè)子系統(tǒng)(煙氣CEMS)、排氣參數(shù)子系統(tǒng)等三部分。

2.2 系統(tǒng)結(jié)構(gòu)

CEMS系統(tǒng)采取了模塊化的結(jié)構(gòu),系統(tǒng)功能單元大致分為室內(nèi)和室外兩部分。室內(nèi)部分主要有主機(jī)柜(樣氣處理、分析儀、數(shù)據(jù)采集處理等)、供電電源、凈化壓縮空氣源。室外部分主要有采樣監(jiān)測(cè)點(diǎn)電源箱、紅外測(cè)塵儀、流速監(jiān)測(cè)儀、煙氣采樣探頭、空氣過(guò)濾器以及伴熱采樣管線和信號(hào)控制電纜等組成。

2.3 氣體監(jiān)測(cè)

煙氣的分析(SO2、NOX、O2)采樣方法采用直接抽取加熱法,分析儀表選用德國(guó)西門(mén)子多組分紅外分析儀ULTTRAMAT23。SO2、NOX紅外分析原理,O2采用電化學(xué)法。

我廠采用直接抽取法進(jìn)行煙氣分析,標(biāo)準(zhǔn)狀態(tài)下的干煙氣是指在溫度273K,壓力為101325Pa條件下不含水汽的煙氣。系統(tǒng)主要由保溫取樣探頭、保溫輸氣管路和制冷除濕預(yù)處理系統(tǒng)組成,測(cè)量較準(zhǔn)確,表計(jì)不準(zhǔn)時(shí)可以隨時(shí)用標(biāo)氣標(biāo)定。

2.4 粉塵監(jiān)測(cè)

我廠采用RBV粉塵儀,基于激光散射原理,基于煙塵粒子的背向散射,鏡頭要經(jīng)常擦拭、污染嚴(yán)重時(shí)要用酒精棉對(duì)其清洗。特別是當(dāng)法蘭焊接在煙囪上后,如果為負(fù)壓,需要連接保護(hù)過(guò)濾器;如果測(cè)點(diǎn)在正壓,需要加反吹,含塵量應(yīng)小于200毫克/方米。如果煙氣中含水量太大會(huì)影響測(cè)量效果,水汽太大,水滴會(huì)被當(dāng)成顆粒物測(cè)量。

2.5 流量測(cè)量

利用皮托管差壓法,皮托管有兩個(gè)測(cè)壓孔,一個(gè)對(duì)準(zhǔn)氣體流動(dòng)方向,測(cè)的是總壓,另一個(gè)垂直于流動(dòng)方向,測(cè)的是靜壓。流速與動(dòng)壓的平方根成正比,為了保證測(cè)量準(zhǔn)確,增加了反吹管路和電磁閥,定時(shí)進(jìn)行吹掃。

2.6 輔助參數(shù)

溫度采用一體化溫度變送器測(cè)量,壓力采用西門(mén)子擴(kuò)散硅微壓變送器。

2.7 數(shù)據(jù)采集處理系統(tǒng)

由計(jì)算機(jī)、打印機(jī)、485-232轉(zhuǎn)換器、相關(guān)軟件。

2.8 氣體預(yù)處理系統(tǒng)

2.8.1 氣體采樣

煙氣經(jīng)采樣探頭和煙氣加熱管線由取樣泵抽到分析柜,氣體伴熱管路為避免從取樣點(diǎn)及分析柜傳輸過(guò)程中不出現(xiàn)樣氣冷凝現(xiàn)象,避免SO2損失及樣氣暢通,取樣管線及取樣探頭均采用加熱方式,其溫度要求控制在120-140度。采樣流程為:樣氣-采樣探頭-采樣管-分水器-制冷器冷槍A-過(guò)濾器FP1-兩位一通電磁閥Y1-制冷器冷槍B-抽氣泵-樣氣、標(biāo)氣切換閥-分析儀表-排氣管路到室外。

2.8.2 真空泵為法國(guó)產(chǎn)KNF耐腐隔膜真空泵。

2.8.3 樣氣過(guò)濾器主要通過(guò)探頭過(guò)濾器和過(guò)濾器組成。

2.8.4 樣氣除水:樣氣進(jìn)入分析柜后,通過(guò)制冷器來(lái)對(duì)樣氣進(jìn)行快速冷凝,經(jīng)過(guò)制冷后的樣氣將滿(mǎn)足分析儀要求。蠕動(dòng)泵用于冷凝水的排放,制冷器的溫度一般控制在+5±2℃,其中包括氣體冷凝、過(guò)濾器和氣流調(diào)節(jié)裝置組成,使煙氣中夾帶的液態(tài)汽溶膠體、水分等冷凝液體,在經(jīng)過(guò)汽水分離器的氣膜時(shí)被捕集,集成液滴沿器壁下落,由出水口排入排水器內(nèi),從而達(dá)到氣液分離的目的,并使樣氣得到進(jìn)一步凈化,并調(diào)節(jié)氣流到一個(gè)合適的流量送入分析儀內(nèi)。

2.8.5 凈化器源:為儀器的氣路提供清掃氣,經(jīng)過(guò)除水干燥,出游凈化處理后的潔凈空氣。主要有:測(cè)塵儀的在線強(qiáng)制吹掃氣路,防止光學(xué)鏡頭污染;用潔凈的壓縮空氣吹掃采樣氣路和采樣探頭。雙管伴熱和吹掃氣路,保證采樣探頭和管路的暢通。

3 分析儀故障分析

3.1 分析儀常見(jiàn)故障代碼有M維護(hù)請(qǐng)求、F有故障、“!”是故障已被記錄在日志中而且不錯(cuò)在。

3.2 煙氣分析儀SO2數(shù)值顯示偏小或不變

(1)當(dāng)現(xiàn)場(chǎng)鍋爐工況偏低或者停爐時(shí),對(duì)SO2影響很大,當(dāng)負(fù)荷高時(shí),燃煤量大,SO2含量高;負(fù)荷波動(dòng)大時(shí),SO2變化也會(huì)大。

(2)當(dāng)采樣氣體流量偏低時(shí)對(duì)SO2有很大影響,一般要求采樣氣體流量保持在0.8-1.2mg/min之間,流量偏低會(huì)使進(jìn)入分析儀的氣量過(guò)小而使得測(cè)量數(shù)值偏低。一般為采樣探頭、管路、控制電磁閥、冷凝器堵塞或冰凍現(xiàn)象,應(yīng)使流量在正常范圍。排氣管、排水管凍管,導(dǎo)致管路堵,分析儀不能正常工作,SO2和O2濃度不準(zhǔn),要盡量提高環(huán)境溫度,避免類(lèi)似現(xiàn)象發(fā)生。

(3)當(dāng)管路存在泄漏現(xiàn)象時(shí),首先會(huì)是氧量偏大,SO2偏低,可能原因是采樣管路、連接接頭、過(guò)濾器、冷凝器、蠕動(dòng)泵管等密封不嚴(yán);從玻璃瓶進(jìn)氣口取下進(jìn)氣管,堵住進(jìn)氣口,如果浮子流量計(jì)小球到最低,且儀表出現(xiàn)報(bào)警說(shuō)明柜內(nèi)各裝置密封良好。精密過(guò)濾器堵導(dǎo)致分析儀沒(méi)進(jìn)氣,導(dǎo)致SO2和氧量濃度不變;蠕動(dòng)泵壞導(dǎo)致系統(tǒng)漏入空氣使分析儀數(shù)據(jù)測(cè)量不準(zhǔn)確。

3.3 采樣氣體流量偏高或偏低

管路漏氣時(shí),流量顯示偏高,SO2偏高,此時(shí)應(yīng)檢查密封。

管路有堵塞時(shí),流量計(jì)顯示偏低且調(diào)整螺釘無(wú)效、SO2偏高,此時(shí)應(yīng)檢查真空泵處理及管路堵塞情況。

4 系統(tǒng)維護(hù)

4.1 在線監(jiān)測(cè)SO2數(shù)據(jù)異常的處理方法

在CEMS小間檢查在線分析儀的流量是否保持在1.0mg/min左右,如果不能調(diào)節(jié),拔下初級(jí)過(guò)濾器前取樣管,觀察分析儀流量是否能升高到2.0mg/min以上,若不能則重點(diǎn)檢查初級(jí)過(guò)濾器、真空泵、氣管、各接頭、冷凝器、氣體排出管是否順暢等。若能,則重點(diǎn)檢查煙氣取樣裝置是否堵塞,重點(diǎn)檢查采樣濾芯、探頭、電磁閥、伴熱管線等;檢查排水蠕動(dòng)泵運(yùn)轉(zhuǎn)及排水、泵的嚴(yán)密性、查看有無(wú)漏氣,最后用標(biāo)準(zhǔn)氣對(duì)分析儀進(jìn)行標(biāo)定

4.2 SO2標(biāo)定步驟

零點(diǎn)標(biāo)定時(shí)按CAL鍵,拔下真空泵入口軟管,自動(dòng)校準(zhǔn)零點(diǎn),要求分析儀流量計(jì)保持在1.0ml/min左右,校準(zhǔn)完后自動(dòng)進(jìn)入測(cè)量狀態(tài)。量程標(biāo)定時(shí)要求通入符合條件的標(biāo)準(zhǔn)氣體。標(biāo)氣濃度單位換算系數(shù):

SO2濃度單位:1μmol/mol=64/22.4mg/m3=2.86 mg/m3

NO濃度單位:1μmol/mol=30/22.4mg/m3=1.34 mg/m3

NO2濃度單位:1μmol/mol=46/22.4mg/m3=2.05 mg/m3

4.3 日常維護(hù)與保養(yǎng)

維護(hù)內(nèi)容包括系統(tǒng)檢查與部件更換,一般包括日常檢查和定期檢查。日常檢查包括對(duì)ULTRAMAT23、保護(hù)過(guò)濾器、制冷器后管路、制冷器、蠕動(dòng)泵、儲(chǔ)液罐、采樣管線、采樣探頭、粉塵儀風(fēng)機(jī)、DAS系統(tǒng)進(jìn)行檢查;定期檢查包括測(cè)塵儀零點(diǎn)及跨度校準(zhǔn)15-30天,流量計(jì)校準(zhǔn)零點(diǎn)、更換機(jī)柜風(fēng)扇濾網(wǎng)、U23量程校準(zhǔn)周期是3-6個(gè)月,更換取樣探頭過(guò)濾器濾芯、蠕動(dòng)泵管及粉塵儀風(fēng)機(jī)濾芯周期為6個(gè)月,更換取樣泵膜片要1-2年,更換電磁閥周期為3年。還要每3個(gè)月對(duì)分析儀進(jìn)行零漂、跨漂校準(zhǔn)并填寫(xiě)校準(zhǔn)記錄。

過(guò)??諝庀禂?shù)α=21%/(21%-XO2);XO2為實(shí)際含氧量

用折算濃度算超標(biāo)C=C?*(α/αS);C為折算濃度,C'標(biāo)干污染物濃度,αS鍋爐標(biāo)準(zhǔn)的

顆粒物和氣態(tài)污染物排放率G= C'*Qsn*10-69(Kg/h); Qsn為標(biāo)干煙氣流量,單位m3/h

環(huán)保部門(mén)的監(jiān)督考核從驗(yàn)收合格后開(kāi)始,每季度企業(yè)自行開(kāi)展比對(duì)監(jiān)測(cè),比對(duì)監(jiān)測(cè)時(shí),生產(chǎn)設(shè)備應(yīng)正常穩(wěn)定運(yùn)行。比對(duì)監(jiān)測(cè)項(xiàng)目有煙氣溫度、煙氣流速、氧量和污染物實(shí)測(cè)濃度(顆粒物、SO2、NOX)。

數(shù)據(jù)統(tǒng)計(jì)方法及判定:

每季度有效數(shù)據(jù)捕集率=(該季度小時(shí)數(shù)-缺失數(shù)據(jù)小時(shí)數(shù)-無(wú)效數(shù)據(jù)小時(shí)數(shù))/(該季度小時(shí)數(shù)-無(wú)效數(shù)據(jù)小時(shí)數(shù))×100%

缺失數(shù)據(jù)時(shí)間段包括:煙氣CEMS故障時(shí)間、維修時(shí)間、失控時(shí)段、參比方法替代時(shí)段以及有計(jì)劃地維護(hù)保養(yǎng)、校準(zhǔn)、校驗(yàn)等煙氣CEMS缺失時(shí)間段。

無(wú)效數(shù)據(jù)時(shí)間段包括:固定污染源起停運(yùn)(大修、中修、小修等)期間以及悶爐等時(shí)間段。

根據(jù)環(huán)保標(biāo)準(zhǔn)規(guī)定煙氣CEMS每季度有效數(shù)據(jù)捕集率應(yīng)達(dá)到75%以上。

參考文獻(xiàn)

第4篇:煙氣監(jiān)測(cè)范文

關(guān)鍵詞: .Net;煙氣;在線監(jiān)測(cè)系統(tǒng)

中圖分類(lèi)號(hào):TM764 文獻(xiàn)標(biāo)識(shí)碼:A 文章編號(hào):1671-7597(2011)1210110-01

國(guó)家統(tǒng)計(jì)局2009年1~9月電力供給結(jié)構(gòu)數(shù)據(jù)顯示,火電占整個(gè)電力供給的80.35%?;鹆Πl(fā)電過(guò)程中會(huì)排放出巨量的二氧化硫,二氧化硫是主要的大氣污染源,可加速酸雨形成,加重污染。因此,國(guó)家環(huán)保部通知,要求各火電機(jī)組必須安裝二氧化硫及煙塵等污染物監(jiān)測(cè)裝置,并接受各地督查中心核查。這就需要一套火電廠在線監(jiān)測(cè)系統(tǒng)對(duì)各火電機(jī)組運(yùn)行狀況、脫硫設(shè)備進(jìn)行實(shí)時(shí)監(jiān)測(cè),該系統(tǒng)的運(yùn)行無(wú)疑對(duì)國(guó)家節(jié)能減排具有重大意義。

火電廠的煙氣監(jiān)測(cè)參數(shù)繁多,涉及的系統(tǒng)設(shè)備復(fù)雜,若操作不慎易導(dǎo)致發(fā)電主機(jī)停機(jī)等影響電網(wǎng)的重大事故。因此必須建立滿(mǎn)足火電廠自身業(yè)務(wù)需求的煙氣在線監(jiān)測(cè)系統(tǒng)。本文設(shè)計(jì)并實(shí)現(xiàn)了一個(gè)基于.NET技術(shù)架構(gòu)的在線監(jiān)測(cè)信息系統(tǒng),該系統(tǒng)應(yīng)用于火電廠的煙氣在線遠(yuǎn)程監(jiān)控,也是環(huán)保部門(mén)進(jìn)行環(huán)境監(jiān)察的有效工具。

火電廠煙氣在線遠(yuǎn)程監(jiān)控管理系統(tǒng)通過(guò)實(shí)時(shí)采集火電廠各項(xiàng)煙氣數(shù)據(jù)和脫硫裝置的運(yùn)行數(shù)據(jù),分析環(huán)保設(shè)施的健康水平,實(shí)現(xiàn)對(duì)煙氣排放指標(biāo)和脫硫裝置運(yùn)行情況的在線遠(yuǎn)程監(jiān)控和分析。針對(duì)中電投下屬約180臺(tái)火電機(jī)組,每臺(tái)機(jī)組考慮100個(gè)數(shù)據(jù)量,主要監(jiān)控各電廠入口和出口CEMS數(shù)據(jù)、脫硫主要設(shè)備運(yùn)行狀態(tài)(包括FGD出入口煙氣參數(shù)、煙氣擋板狀態(tài)、增壓風(fēng)機(jī)、GGH、循環(huán)泵運(yùn)行狀態(tài)以及其它參數(shù))。

通過(guò)本系統(tǒng)的建設(shè),實(shí)現(xiàn)對(duì)整個(gè)集團(tuán)電廠脫硫裝置主要設(shè)備的監(jiān)視和主要參數(shù)排量分析,真實(shí)掌握各電廠脫硫裝置的實(shí)時(shí)生產(chǎn)信息,加強(qiáng)對(duì)電廠的監(jiān)管力度和分析,同時(shí)為集團(tuán)領(lǐng)導(dǎo)決策提供更有效的依據(jù)。

1 系統(tǒng)工作流程

系統(tǒng)按數(shù)據(jù)采集、數(shù)據(jù)存儲(chǔ)、分析應(yīng)用(含GIS應(yīng)用)三個(gè)步驟進(jìn)行工作。首先從火電廠脫硫裝置或CEMS獲取煙氣監(jiān)測(cè)數(shù)據(jù),通過(guò)網(wǎng)絡(luò)和接口系統(tǒng)上傳,存儲(chǔ)到SCADA數(shù)據(jù)庫(kù),完成數(shù)據(jù)采集工作,從SCADA數(shù)據(jù)庫(kù)將數(shù)據(jù)處理后轉(zhuǎn)儲(chǔ)到SQL SERVER數(shù)據(jù)庫(kù),同時(shí)建立GIS數(shù)據(jù)庫(kù),完成數(shù)據(jù)存儲(chǔ)工作,在SQL SERVER數(shù)據(jù)庫(kù)、GIS數(shù)據(jù)庫(kù)以及SCADA提供的實(shí)時(shí)數(shù)據(jù)的支持下,實(shí)現(xiàn)曲線分析、工藝流程圖,運(yùn)行報(bào)警、統(tǒng)計(jì)報(bào)表、地圖導(dǎo)航、污染擴(kuò)散分析等功能,完成數(shù)據(jù)分析應(yīng)用工作。

2 系統(tǒng)網(wǎng)絡(luò)結(jié)構(gòu)

如圖1所示,系統(tǒng)網(wǎng)絡(luò)結(jié)構(gòu)可劃分為電廠無(wú)線接入網(wǎng)絡(luò),電廠有線接入網(wǎng)絡(luò),監(jiān)控中心局域網(wǎng),InterNet接入網(wǎng)四個(gè)部分。電廠到監(jiān)控中心之間不采用InterNet,是為了保證電廠監(jiān)控系統(tǒng)不受干擾。

2.1 電廠無(wú)線接入網(wǎng)絡(luò)電廠到監(jiān)控中心之間如果無(wú)有線專(zhuān)網(wǎng)互聯(lián),采用CDMA/GPRS無(wú)線網(wǎng)方式實(shí)現(xiàn)互聯(lián),電廠端安裝CDMA無(wú)線數(shù)傳終端,數(shù)據(jù)通過(guò)CDMA/GPRS網(wǎng)絡(luò)傳輸?shù)诫娦判畔⒅行模娦判畔⒅行呐c煙氣監(jiān)控中心之間以專(zhuān)線連接,為保證安全,中間以防火墻進(jìn)行隔離。CDMA網(wǎng)絡(luò)采用TCP/IP協(xié)議通信,永久在線,速度在80-120K/S,完全滿(mǎn)足本系統(tǒng)連續(xù)數(shù)據(jù)采集傳輸?shù)囊蟆?/p>

2.2 電廠有線接入網(wǎng)絡(luò)

電廠到監(jiān)控中心之間存在有線專(zhuān)網(wǎng),只需將監(jiān)控中心接入專(zhuān)網(wǎng)即可,中間以防火墻隔離,數(shù)據(jù)傳輸通過(guò)有線專(zhuān)網(wǎng)完成。

2.3 監(jiān)控中心局域網(wǎng)

設(shè)計(jì)為1000M局域網(wǎng),配置與無(wú)線、有線專(zhuān)網(wǎng)以及InterNet互聯(lián)的路由器和防火墻,配置兩臺(tái)實(shí)時(shí)數(shù)據(jù)采集服務(wù)器,供安裝監(jiān)控組態(tài)軟件、實(shí)時(shí)/歷史數(shù)據(jù)庫(kù)和應(yīng)用數(shù)據(jù)庫(kù),二者互相備份,配置GIS服務(wù)器,供安裝GIS平臺(tái)軟件,配置域名服務(wù)器,提供域名解分析服務(wù),配置防病毒服務(wù)器,實(shí)現(xiàn)局域網(wǎng)病毒監(jiān)控,配置Web應(yīng)用服務(wù)器,通過(guò)Internet向終端用戶(hù)煙氣在線監(jiān)控服務(wù)的各項(xiàng)功能。配置GIS和SCADA工作站終端,供系統(tǒng)的管理維護(hù)。

2.4 InterNet接入網(wǎng)

監(jiān)控中心局域網(wǎng)與InterNet之間采用專(zhuān)線連接,中間以防火墻隔離,并為Web服務(wù)器申請(qǐng)互聯(lián)網(wǎng)IP地址。

圖1 火電廠煙氣在線遠(yuǎn)程監(jiān)控系統(tǒng)網(wǎng)絡(luò)結(jié)構(gòu)

3 系統(tǒng)設(shè)計(jì)與實(shí)現(xiàn)中解決的核心問(wèn)題

3.1 .NET平臺(tái)上多個(gè)獨(dú)立系統(tǒng)的集成

火電廠遠(yuǎn)程在線監(jiān)控系統(tǒng)的特點(diǎn)是需要從多個(gè)火電廠采集煙氣監(jiān)控實(shí)時(shí)數(shù)據(jù),進(jìn)行集中管理,分析應(yīng)用,是SCADA,GIS,關(guān)系數(shù)據(jù)庫(kù)技術(shù)在.NET平臺(tái)上的集成應(yīng)用。SCADA完成遠(yuǎn)程數(shù)據(jù)采集和存儲(chǔ),為系統(tǒng)分析提供實(shí)時(shí)數(shù)據(jù)源,GIS和AERMOD系統(tǒng)完成基于地圖的數(shù)據(jù)分析展示、污染擴(kuò)散分析,關(guān)系數(shù)據(jù)庫(kù)則二次存儲(chǔ)SCADA的實(shí)時(shí)/歷史數(shù)據(jù),完成更高層次的分析統(tǒng)計(jì)。

3.2 便于擴(kuò)展和維護(hù)的系統(tǒng)架構(gòu)

系統(tǒng)嚴(yán)格按模塊化結(jié)構(gòu)設(shè)計(jì),使用配置文件、錯(cuò)誤日志、提高數(shù)據(jù)庫(kù)

設(shè)計(jì)通用性、減少第三方插件使用等措施,提高系統(tǒng)的可擴(kuò)展性和可維護(hù)性。

3.3 系統(tǒng)的可用性和安全性

系統(tǒng)采用多種性能優(yōu)化措施提高人機(jī)交互性能,縮短響應(yīng)時(shí)間,提高可用性。從軟件、硬件多個(gè)角度采取措施保證系統(tǒng)數(shù)據(jù)安全,提高安全性。

3.4 完善的監(jiān)控及分析功能,較強(qiáng)的實(shí)用性

針對(duì)脫硫監(jiān)控和環(huán)保督察業(yè)務(wù),開(kāi)發(fā)了曲線分析、工藝流程圖,實(shí)時(shí)參數(shù)監(jiān)測(cè)、統(tǒng)計(jì)報(bào)表、專(zhuān)題圖、擴(kuò)散分析等模塊,對(duì)電力和環(huán)保部門(mén)都有很大的實(shí)用價(jià)值。

參考文獻(xiàn):

[1]曾登高,Net系統(tǒng)架構(gòu)與開(kāi)發(fā)[M].2003.

[2]吳志強(qiáng),基于.NET架構(gòu)的人力資源管理信息系統(tǒng)[D].西南交通大學(xué),2005.

[3]王振明等,SCADA(監(jiān)控與數(shù)據(jù)采集)軟件系統(tǒng)的設(shè)計(jì)與開(kāi)發(fā)[M].北京:機(jī)械工業(yè)出版社,2009.

第5篇:煙氣監(jiān)測(cè)范文

關(guān)鍵詞:SCS-900型煙氣排放連續(xù)監(jiān)測(cè)系統(tǒng);SO2數(shù)據(jù)跳變;環(huán)保超排事件

Abstract: This paper analyzes and solves the problem of the SO2 data jump of SCS-900 type flue gas emission monitoring system in Xinyang project department, which is a Limited by Share Ltd of Datang environmental industry group. Through the comprehensive analysis of SCS-900 type flue gas emission monitoring system, the factors that cause the SCS-900 type flue gas emission monitoring system to jump in the running of SO2 data are summarized, and the problem of SO2 data's jump in the running of SCS-900 type flue gas emission monitoring system is solved.

SCS-900型煙氣排放連續(xù)監(jiān)測(cè)氣體分析系統(tǒng)由采樣探頭、取樣管線、樣品預(yù)處理系統(tǒng)、氣體分析儀表、分析儀表柜等組成。超凈排放改造之后,脫硫出口排放標(biāo)準(zhǔn)降由200mg/Nm3降低至35mg/Nm3,脫硫運(yùn)行調(diào)控幅度大大減小。脫硫出口SO2測(cè)量數(shù)值跳變將直接影響脫硫系統(tǒng)正常運(yùn)行和環(huán)保達(dá)標(biāo)排放。

大唐環(huán)境產(chǎn)業(yè)集團(tuán)有限公司信陽(yáng)項(xiàng)目部#2機(jī)組脫硫煙氣在線監(jiān)測(cè)分析系統(tǒng)采用北京雪迪龍公司SCS-900型煙氣排放連續(xù)監(jiān)測(cè)設(shè)備,在#2機(jī)組脫硫系統(tǒng)超低排放改造投運(yùn)之后出現(xiàn)脫硫出口SO2測(cè)量數(shù)值頻繁跳變現(xiàn)象。在機(jī)組負(fù)荷無(wú)變化、煙氣流量穩(wěn)定、循環(huán)泵正常運(yùn)行、供漿流量等各項(xiàng)參數(shù)均正常的情況下,脫硫出口SO2實(shí)測(cè)量值出現(xiàn)由正常測(cè)量值(10-30 mg/Nm3)在2分鐘內(nèi)上升至異常值(35-100)mg/Nm3異?,F(xiàn)象。異常值持續(xù)3-5分鐘之后緩慢降低至正常值,這種現(xiàn)象易造成小時(shí)均值環(huán)保超排事件。

1 系統(tǒng)檢查

1.1 取樣探頭安裝檢查:取樣探頭箱安裝向下傾斜5-10°,符合Q/CPXDL0002-2012 SCS-900煙氣連續(xù)監(jiān)測(cè)系統(tǒng)(煙氣分析儀)安裝規(guī)范。

1.2 采樣加熱探桿加熱溫度135℃:溫度正常。

1.3 探頭箱螺旋加熱器加熱溫度135℃:溫度正常。

1.4 取樣管線加熱溫度140℃:溫度正常。

1.5 NO-NOx轉(zhuǎn)換器溫度180℃:溫度正常。

1.6 制冷器制冷溫度2℃:溫度正常。

1.7 ULTRAMAT 23儀表標(biāo)氣校準(zhǔn)數(shù)據(jù)正常,儀表運(yùn)行正常。

1.8 樣氣流量1.0~1.5L/min:樣氣流量正常。

1.9 煙氣溫度45~50℃,濕度8%~12%,樣氣預(yù)處理管內(nèi)壁附著凝結(jié)水。

2 原因分析

在MODEL2061正常工作情況下,煙道里面的樣氣由取樣泵(DP1)抽取,經(jīng)采樣加熱探桿、加熱探頭、取樣管線加熱溫度維持在140℃樣氣呈氣態(tài),當(dāng)樣氣流經(jīng)管線(L1)、電磁閥(M1)、管線(L2)時(shí),處于管線處于室溫,樣氣冷凝在管壁形成凝結(jié)水,樣氣中的SO2易溶于水(1體積水能溶解2體積二氧化硫),形成含有高濃度SO2的凝結(jié)水。當(dāng)這些凝結(jié)水經(jīng)MODEL2061高溫加熱時(shí),SO2迅速揮發(fā),L3管線中的SO2濃度迅速增加,ULTRAMAT 23儀表測(cè)量出的SO2濃度數(shù)值迅速增大,形成SO2濃度數(shù)值跳變現(xiàn)象。

3 處理措施

在管線(L1)、電磁閥(M1)本體、管線(L2)敷設(shè)伴熱帶并做好保溫,控制加熱溫度在140℃。

4 處理結(jié)果

樣氣在管線(L1)、電磁閥(M1)、管線(L2)內(nèi)壁呈高溫氣態(tài),消除含有高濃度SO2的凝結(jié)水,從而消除SO2濃度數(shù)值跳變現(xiàn)象。

結(jié)束語(yǔ)

通過(guò)對(duì)以上處理,汲取經(jīng)驗(yàn),對(duì)其它機(jī)組做了同樣處理。消除SO2濃度數(shù)值跳變現(xiàn)象,避免了環(huán)保超排事件,保證了脫硫穩(wěn)定運(yùn)行。

參考文獻(xiàn)

[1]HJ/76-2007 固定污染源排放煙氣連續(xù)監(jiān)測(cè)系統(tǒng)技術(shù)要求及檢測(cè)方法.

[2]HJ/75-2007 固定污染源排放煙氣連續(xù)監(jiān)測(cè)系統(tǒng)驗(yàn)收技術(shù)規(guī)范.

[3]HJ/T 212-2007污染源在線自動(dòng)監(jiān)控(監(jiān)測(cè))系統(tǒng)數(shù)據(jù)傳輸標(biāo)準(zhǔn).

[4]GB/16157-1996 固定污染源排氣中顆粒物測(cè)定與氣態(tài)污染物采樣方法.

[5]HJ/T 47-1999 煙氣采樣器技術(shù)條件.

第6篇:煙氣監(jiān)測(cè)范文

關(guān)鍵詞:氮氧化物(NOX)、煙氣組份分析儀(NH3/NOx/O2)、應(yīng)用分析

中圖分類(lèi)號(hào):TU834.6+34 文獻(xiàn)標(biāo)識(shí)碼:A 文章編號(hào):

0 引言

氮氧化物(NOX)是造成大氣污染的主要污染源之一,是形成酸雨、酸霧的主要原因之一,NOX與碳?xì)浠衔镄纬晒饣瘜W(xué)煙霧,NOX亦參與臭氧層的破壞,是破壞生態(tài)環(huán)境和損害人體健康的重要污染源之一,而我國(guó)以煤炭為主的能源結(jié)構(gòu)導(dǎo)致NOx排放總量居高不下,“十一五”期間,NOx排放的快速增長(zhǎng)加劇了復(fù)合型大氣污染的形成,部分抵消了SO2減排的巨大努力。為減少鍋爐NOx的排放,改善當(dāng)?shù)卮髿猸h(huán)境,適應(yīng)新的環(huán)保政策,江蘇徐塘發(fā)電有限責(zé)任公司決定對(duì)4、5號(hào)鍋爐進(jìn)行煙氣脫硝改造,從而提出了對(duì)氮氧化物(NOX)的準(zhǔn)確測(cè)量問(wèn)題。

1工程概述

“江蘇徐塘發(fā)電有限責(zé)任公司2×320MW機(jī)組煙氣脫硝工程”,采用液氨法制備脫硝還原劑,選擇性催化還原法(SCR)作為脫硝裝置及配套系統(tǒng)改造。控制NOx濃度由500 mg/Nm3降低到75mg/Nm3(設(shè)計(jì)SCR效率85%),

脫硝裝置性能主要如下:

脫硝裝置在性能考核試驗(yàn)時(shí)(附加層催化劑不投運(yùn))的NOX脫除率不小于85%,保證出口小于75 mg/Nm3,氨的逃逸率小于2.5ppm,SO2/SO3轉(zhuǎn)化率小于1%;

a) 鍋爐50%THA~100%BMCR負(fù)荷;

b) 煙氣入口NOX含量不大于(500)mg/Nm3;

c) 脫硝裝置入口煙氣含塵量小于(42)g/Nm3;

d) 煙氣出口NOX含量低于(75)mg/Nm3;

e)NH3/NOx摩爾比不超過(guò)保證值( 0.86)時(shí)。

脫硝效率定義:

脫硝= C1-C2 ×100%

C1

式中:C1——脫硝系統(tǒng)運(yùn)行時(shí)脫硝入口處煙氣中NOX含量(mg/Nm3)。

C2——脫硝系統(tǒng)運(yùn)行時(shí)脫硝出口處煙氣中NOX含量(mg/Nm3)。

氨的逃逸率是指在脫硝裝置出口的氨的濃度。

2.分析儀(NH3/NOx/O2)系統(tǒng)構(gòu)成

分析儀系統(tǒng)圖如圖1 (NH3/NOx/O2)

圖1

2.1 測(cè)量系統(tǒng)分析

整套監(jiān)測(cè)系統(tǒng)的前端監(jiān)測(cè)探頭安裝在污染源監(jiān)測(cè)點(diǎn)位置,監(jiān)測(cè)信號(hào)經(jīng)變送器轉(zhuǎn)換處理后變?yōu)閿?shù)字信號(hào),由標(biāo)準(zhǔn)RS485串行接口傳輸?shù)奖镜乇O(jiān)控計(jì)算機(jī),本地監(jiān)控計(jì)算機(jī)和分析系統(tǒng)機(jī)柜放置在專(zhuān)用監(jiān)測(cè)室內(nèi),在監(jiān)控計(jì)算機(jī)上通過(guò)與之配套的在線環(huán)境監(jiān)測(cè)網(wǎng)絡(luò)系統(tǒng)對(duì)污染源氮氧化物(NOX)、NH3、溫度、含氧量和壓力等環(huán)境參數(shù)進(jìn)行數(shù)據(jù)采集處理,以實(shí)現(xiàn)環(huán)境參數(shù)自動(dòng)化數(shù)據(jù)報(bào)表處理和統(tǒng)計(jì)工作,并可通過(guò)電話(huà)網(wǎng)絡(luò)或Internet網(wǎng)將監(jiān)測(cè)數(shù)據(jù)傳送到環(huán)境監(jiān)測(cè)中心站或其他相關(guān)部門(mén)。也可選用模擬端口,或干接觸進(jìn)行參數(shù)傳輸或設(shè)備的控制。

系統(tǒng)采用完全抽取法采集樣氣,過(guò)濾后通過(guò)伴熱管線傳輸氣體,樣氣在分析儀前完成處理,使之成為干態(tài)的待測(cè)氣體進(jìn)入分析儀器進(jìn)行檢測(cè)。氣體分析采用交替進(jìn)樣法及非分散紅外原理檢測(cè)樣氣。測(cè)量結(jié)果通過(guò)數(shù)字端口輸入到數(shù)據(jù)采集設(shè)備。數(shù)據(jù)管理軟件對(duì)原始數(shù)據(jù)進(jìn)行處理,生成各種形式的報(bào)告,并可進(jìn)行遠(yuǎn)程傳輸。

此外,為保障系統(tǒng)正常運(yùn)行,系統(tǒng)設(shè)計(jì)了多種診斷和報(bào)警功能??奢敵鰣?bào)警信號(hào)、作數(shù)椐標(biāo)記或發(fā)出控制信號(hào),如停止采樣、啟動(dòng)反吹等。系統(tǒng)具有反吹、校準(zhǔn)功能,它可以編程自動(dòng)進(jìn)行,也可以隨時(shí)手動(dòng)實(shí)施。校準(zhǔn)使用標(biāo)準(zhǔn)鋼瓶氣,可直接校準(zhǔn)分析部分,也可通過(guò)探頭進(jìn)行總體校準(zhǔn)。

系列采用了具有創(chuàng)新性的三段脫水系統(tǒng)。該系統(tǒng)包括了一個(gè)水分分離器和兩個(gè)電子冷卻器。脫水系統(tǒng)的完美設(shè)計(jì)可確保將冷凝水帶走的NOx等損失量降低到最低限度,從而保證了監(jiān)測(cè)數(shù)據(jù)的準(zhǔn)確性。

2.2對(duì)氮氧化物(NOX)的測(cè)量分析

在脫硝系統(tǒng)前后分別對(duì)NOx進(jìn)行監(jiān)測(cè),可以讓我們了解脫硝系統(tǒng)的效率。對(duì)氮氧化物(NOX)測(cè)量原理一般有:化學(xué)發(fā)光法(CLD)、非分散紅外吸收法(NDIR)、紫外吸收法(UV)三種。本系統(tǒng)采用獨(dú)特的交替流動(dòng)調(diào)制化學(xué)發(fā)光法(CLD),從原理上消除了零點(diǎn)漂移,此外樣氣、零氣交替進(jìn)入同一個(gè)簡(jiǎn)冊(cè)池,更進(jìn)一步儀器本身不同帶來(lái)的誤差。NOX監(jiān)測(cè)單元采用了低溫NOX轉(zhuǎn)化器,在一種特殊的碳族催化劑作用下,將NO2轉(zhuǎn)化成NO.。該轉(zhuǎn)化器的工作溫度約為190℃,在確保NO2完全轉(zhuǎn)化為NO的同時(shí),耐用性和壽命大大提高,采用半導(dǎo)體傳感器,能夠測(cè)量0-10ppm微小含量的組份,比傳統(tǒng)的傳感器使用壽命更長(zhǎng),靈敏度、可靠性進(jìn)一步提高。

如圖2,在電磁閥的精確控制下,樣氣和參比氣(待測(cè)成分濃度為零或?yàn)槟硞€(gè)已知數(shù)的氣體)以恒定的流量被交替地注入檢測(cè)池內(nèi)。紅外線光源發(fā)出的紅外線通過(guò)檢測(cè)池后被檢測(cè)器檢測(cè)。當(dāng)檢測(cè)池內(nèi)順序通入樣氣和參比氣時(shí),對(duì)紅外線能量的吸收就會(huì)產(chǎn)生變化,致使檢測(cè)器中的薄片產(chǎn)生位移,位移被轉(zhuǎn)化成電信號(hào),最后計(jì)算出樣氣中待測(cè)成分的濃度。

圖2

2.3NH3監(jiān)測(cè)的意義及SCR氨逃逸量測(cè)量分析

由于在脫硝過(guò)程中需要噴入NH3,所以需要對(duì)脫硝過(guò)程后殘留的NH3進(jìn)行監(jiān)測(cè),以保證最終的排放濃度在排放標(biāo)準(zhǔn)以?xún)?nèi)。在線監(jiān)測(cè)系統(tǒng)的數(shù)據(jù)不但可以向相關(guān)部門(mén)匯報(bào),而且可以直接作為脫硝過(guò)程中的過(guò)程控制參數(shù),防止過(guò)多的NH3與SO3反應(yīng)形成 NH4HSO3,通過(guò)有效利用NH3降低脫硝運(yùn)行成本 。

由于NH3極易溶于水,造成測(cè)量不準(zhǔn),其對(duì)策主要是采用探頭還原反應(yīng)方式測(cè)量NH3,探頭處溫度比較高,可以防止NH3損失,由于探頭深入煙道內(nèi),易于保持反應(yīng)所需溫度。本工程煙氣脫硝入口及出口氮氧化物監(jiān)測(cè)的在線分析采取直接抽取法,其難點(diǎn)在于被測(cè)煙氣高溫、高粉塵、高濕及高腐蝕,造成取樣探頭易堵塞,系統(tǒng)易腐蝕。因此對(duì)采樣及樣氣處理系統(tǒng)采取多級(jí)過(guò)濾除塵,兩級(jí)除濕,采取氣溶膠過(guò)濾除霧滴等措施,提高系統(tǒng)除塵、除濕的能力,確保系統(tǒng)可靠運(yùn)行。

3.日常維護(hù)檢查項(xiàng)目

為了保證系統(tǒng)的正常運(yùn)行,必須進(jìn)行定期的檢查和維護(hù),如表1

表1

4.常見(jiàn)故障對(duì)應(yīng)

由于分析系統(tǒng)工作環(huán)境惡劣,系統(tǒng)會(huì)出現(xiàn)一些故障,及時(shí)迅速的消除故障,不僅能夠保證主系統(tǒng)的安全運(yùn)行,也可以延長(zhǎng)分析儀的運(yùn)行壽命。

4.1低流量-流量報(bào)警

現(xiàn)象:樣氣或標(biāo)氣濃度不能達(dá)到正常流量。

對(duì)應(yīng):

① 調(diào)整針閥(NV-1、NV-2);

② 確認(rèn)采樣泵運(yùn)行情況(P-1),更換泵膜或者泵;

③ 檢查二次過(guò)濾器是否阻塞(F-1/F-2),更換濾紙;

④ 檢查P-2運(yùn)行情況,更換泵膜;

⑤ 確認(rèn)空氣過(guò)濾器(FA-1)是否堵塞,更換空氣過(guò)濾器;

⑥ 檢查壓力調(diào)節(jié)器(R-1)的設(shè)定壓力和運(yùn)行情況

設(shè)定壓力:-0.01MPa;重新設(shè)定壓力或者更換壓力調(diào)節(jié)器;

⑦ 檢查氣路流程上其他相關(guān)部件是否有堵塞,或者漏氣。

4.2取樣溫度異常

現(xiàn)象:操作面板上’SAMPLING 溫度異常’變紅色

對(duì)應(yīng):

① 檢查電子冷卻器(C-1,C-2)是否正常運(yùn)行,如果異常請(qǐng)更換;

② 確認(rèn)臭氧分解器加熱器(DO-1)是否運(yùn)行,如果異常請(qǐng)更換。

4.3NH3測(cè)量數(shù)據(jù)異常

現(xiàn)象:NH3測(cè)量數(shù)值波動(dòng)異?;蛘邷y(cè)試值異常;

對(duì)應(yīng):

① 調(diào)整NOx氣路與NOx-NH3氣路管路系數(shù),確保兩管路測(cè)量同一氣體時(shí)測(cè)試值一致;

② 對(duì)分析儀進(jìn)行校正;

③ 更換探頭NH3轉(zhuǎn)換催化劑;

④ 更換NOx氣路與NOx-NH3氣路轉(zhuǎn)化催化劑管(COM-1,COM-2)。

4.4不能正常校正

現(xiàn)象:零氣或量程氣校正系數(shù)超過(guò)設(shè)定范圍,操作面板‘校正不能’變紅色

對(duì)應(yīng):

① 確認(rèn)標(biāo)氣流量是否正常,如果流量偏低,按照上面所述排除故障;

確認(rèn)氣瓶壓力,如果氣瓶壓力過(guò)低或者無(wú)壓力,請(qǐng)更換氣瓶

② 檢查校正氣體設(shè)定濃度值是否與氣瓶濃度值一致;

③ 確認(rèn)電磁閥(SV-1,2,3,6)運(yùn)行情況:如果電磁閥停止運(yùn)行,操作面板上‘電磁閥停止’會(huì)變紅色,更換電磁閥。

5 結(jié)束語(yǔ)

第7篇:煙氣監(jiān)測(cè)范文

【關(guān)鍵詞】:壓力容器;無(wú)損檢測(cè);磁粉檢測(cè);滲透檢測(cè);渦流檢測(cè)

中圖分類(lèi)號(hào):O6-335 文獻(xiàn)標(biāo)識(shí)碼:A 文章編號(hào):

從特種設(shè)備發(fā)生事故的教訓(xùn)來(lái)分析,特種設(shè)備安全歸屬技術(shù)系統(tǒng)。壓力容器檢驗(yàn)的實(shí)質(zhì)是失效的預(yù)測(cè)和預(yù)防。其中表面無(wú)損檢測(cè)主要分為磁粉檢測(cè)和滲透檢測(cè)。對(duì)于鐵磁性材料,《壓力容器無(wú)損檢測(cè)》(B4730-2005)標(biāo)準(zhǔn)規(guī)定,應(yīng)優(yōu)先選用磁粉檢測(cè)。這是由于磁粉檢測(cè)相對(duì)于滲透檢測(cè)具有靈敏度高、效率高、成本低、缺陷顯示直觀的優(yōu)點(diǎn)。同時(shí)在實(shí)際檢驗(yàn)中大量缺陷幾乎都是由磁粉檢測(cè)首先發(fā)現(xiàn)的,由此可見(jiàn),磁粉檢測(cè)方法是在用壓力容器定期檢驗(yàn)首選的無(wú)損檢測(cè)方法。

一、無(wú)損檢測(cè)技術(shù)

無(wú)損檢測(cè)在承壓設(shè)備上應(yīng)用時(shí),應(yīng)在遵循承壓設(shè)備安全技術(shù)法規(guī)和相關(guān)產(chǎn)品標(biāo)準(zhǔn)及有關(guān)技術(shù)文件和圖樣規(guī)定的基礎(chǔ),根據(jù)承壓設(shè)備結(jié)構(gòu)、材質(zhì)、制造方法、介質(zhì)、使用條件和失效模式,選擇最合適的無(wú)損檢測(cè)方法。射線和超聲檢測(cè)適用于檢測(cè)承壓設(shè)備的內(nèi)部缺陷;磁粉檢測(cè)適用于檢測(cè)鐵磁性材料制承壓設(shè)備表面和近表面缺陷;滲透檢側(cè)適用于檢測(cè)非多孔性金屬材料和非金屬材料制承壓設(shè)備表面開(kāi)口缺陷;渦流檢測(cè)適用于檢測(cè)導(dǎo)電金屬材料制承壓設(shè)備表面和近表面缺陷。

凡鐵磁性材料制作的承壓設(shè)備和零部件,應(yīng)采用磁粉檢測(cè)方法檢測(cè)表面或近表面缺陷,確因結(jié)構(gòu)形狀等原因不能采用磁粉檢測(cè)時(shí),方可采用滲透檢測(cè)。當(dāng)采用兩種或兩種以上的檢測(cè)方法對(duì)承壓設(shè)備的同一部位進(jìn)行檢測(cè)時(shí),應(yīng)符合各自的合格級(jí)別,如采用同種檢測(cè)方法的不同檢測(cè)工藝進(jìn)行檢測(cè),當(dāng)檢測(cè)結(jié)果不一致時(shí),應(yīng)以危險(xiǎn)度大的評(píng)定級(jí)別為準(zhǔn)。

二、磁粉檢測(cè)技術(shù)

磁粉檢測(cè),又稱(chēng)磁粉檢驗(yàn)或磁粉探傷,屬于無(wú)損檢測(cè)五大常規(guī)方法之一。磁粉檢測(cè)是利用鐵磁性材料被磁化后,由于不連續(xù)的存在,使工件表面和近表面的磁力線發(fā)生局部畸變而產(chǎn)生漏磁場(chǎng)(即磁感應(yīng)線離開(kāi)和進(jìn)入表面時(shí)形成的磁場(chǎng))吸附施加在工件表面的磁粉,形成在合適光照下目視可見(jiàn)的磁痕,從而顯示出不連續(xù)性的位置、形狀、大小和嚴(yán)重程度??蓹z出鐵磁性材料中裂紋、發(fā)紋、白點(diǎn)、折疊、夾雜物等缺陷,具有很高的檢測(cè)靈敏度。

(一)磁粉法的優(yōu)點(diǎn)

磁粉法的優(yōu)點(diǎn)有:(1)能直觀顯示缺陷的形狀、位置、大小,并可大致確定其性質(zhì);(2)具有高的靈敏度,可檢出最小長(zhǎng)度為 0.1mm,寬度為微米級(jí)的裂紋;(3)幾乎不受試件大小和形狀的限制;(4)檢測(cè)速度快,工藝簡(jiǎn)單,費(fèi)用低廉。

(二)局限性

局限性有:(1)只能用于鐵磁性材料;(2)只能發(fā)現(xiàn)表面和近表面缺陷,可探測(cè)的深度一般在 1 ~ 2mm;(3)磁化場(chǎng)的方向應(yīng)與缺陷的主平面相交,夾角應(yīng)在 45°~ 90°,有時(shí)還需從不同方向進(jìn)行多次磁化;(4)不能確定缺陷的埋深和自身高度;(5)寬而淺的缺陷也難以檢出;(6)也不是所有鐵磁性材料都能采用,鐵素體鋼當(dāng)磁場(chǎng)強(qiáng)度 H ≤ 2500A/m 時(shí),相對(duì)磁導(dǎo)率應(yīng)是 μr>300,不銹鋼的鐵素體含量應(yīng)大于 >70%;(7)檢測(cè)后常需退磁和清洗;(8)試件表面不得有油脂或其他能粘附磁粉的物質(zhì)。

磁粉檢測(cè)、滲透檢測(cè)和渦流檢測(cè)都屬于表面無(wú)損檢測(cè)方法,但其原理和適用范圍區(qū)別很大,并且有各自的優(yōu)點(diǎn)和局限性。作為容器檢測(cè)人員應(yīng)熟練掌握這 3 種檢測(cè)方法,并能根據(jù)工件材料、狀態(tài)和檢測(cè)要求,選擇合理的方法進(jìn)行檢測(cè)。例如磁粉檢測(cè)對(duì)鐵磁性材料工件的表面和近表面缺陷具有很高的檢測(cè)靈敏度,可發(fā)現(xiàn)微米級(jí)寬度的小缺陷,所以在容器檢驗(yàn)中對(duì)于鐵磁性材料工件表面和近表面缺陷的檢測(cè)宜優(yōu)先選擇磁粉檢測(cè)方法,確因工件結(jié)構(gòu)形狀等原因不能使用磁粉檢測(cè)時(shí),方可使用滲透檢測(cè)或渦流檢測(cè)。

三、檢測(cè)方法應(yīng)用

由于壓力容器用材料大多為 Q235、16MnR 等碳素鋼或低合金鋼,具低剩磁、低矯頑力的特點(diǎn),故在用壓力容器磁粉探傷只能采用連續(xù)法,即在外加磁場(chǎng)磁化的同時(shí),將磁粉或磁懸液施加到工件上進(jìn)行磁粉探傷。盡管磁粉探傷方法多種多樣,但由于壓力容器定檢磁粉探傷主要是針對(duì)焊縫,包括對(duì)接焊縫、角焊縫等,一般無(wú)法使用固定式設(shè)備,只能用便攜式設(shè)備分段探傷,致使壓力容器定檢對(duì)磁粉探傷方法的選擇受到局限,目前常用的方法有以下幾種:

(一)磁軛法

應(yīng)用較為廣泛,該方法設(shè)備簡(jiǎn)單,操作方便,活動(dòng)關(guān)節(jié)磁軛可檢角焊縫,使用中為檢出各個(gè)方向的缺陷,必須在同一部位至少作兩次互相垂直的探傷,且應(yīng)將焊縫劃分為若干個(gè)受檢段,檢測(cè)操作時(shí)應(yīng)有一定的重疊,此方法效率低,操作不當(dāng)可能造成漏檢。

(二)交叉磁軛法

目前容器定檢中應(yīng)用最廣的一種方法,可產(chǎn)生旋轉(zhuǎn)磁場(chǎng),探傷效率高,靈敏度高,操作簡(jiǎn)單,一次磁化可檢出各方向的缺陷,適于長(zhǎng)的對(duì)接焊縫探傷,對(duì)角焊縫則不適用。

(三)觸頭法

屬單方向磁化方法,電極間距可以調(diào)節(jié),可根據(jù)探傷部位情況及靈敏度要求確定電極間距和電流大小,對(duì)于角焊縫可靈活調(diào)節(jié),該方法和磁軛法一樣,同一部位也要進(jìn)行兩次互相交叉垂直的探傷。

(四)線圈法

對(duì)于管道圓周及管角接焊縫可以用繞電纜法探傷,屬縱向磁化,可發(fā)現(xiàn)焊縫及熱影響區(qū)的縱向裂紋。

在實(shí)際的壓力容器定檢中我所主要使用的只有磁軛法和交叉磁法兩種。對(duì)于容器對(duì)接的縱、環(huán)焊縫,此兩種方法操作方便、靈敏度高、效率高處于無(wú)可替代的地位;對(duì)于接管角焊縫,交叉磁法無(wú)法檢驗(yàn);活動(dòng)關(guān)節(jié)磁軛能較好的解決與容器筒體垂直的接管角焊縫探傷,但對(duì)于成一定角度的接管角焊縫則存在一定的困難;而觸頭法和線圈法則能較好的解決此問(wèn)題。

四、檢測(cè)時(shí)的注意事項(xiàng)

盡管磁粉探傷靈敏度高,但如果操作不當(dāng)也會(huì)造成漏檢,不但發(fā)揮不出磁粉探傷的優(yōu)勢(shì),反而會(huì)因漏檢而給壓力容器的安全運(yùn)行帶來(lái)隱患,對(duì)檢驗(yàn)單位的聲譽(yù)造成不良影響。根據(jù)我在壓力容器定檢中對(duì)磁粉探傷的體會(huì),認(rèn)為容器定檢中磁粉探傷應(yīng)注意以下幾個(gè)問(wèn)題:

(一)檢測(cè)前充分了解容器材料、制造、使用情況在用壓力容器表面檢測(cè)的目的主要是檢查疲勞裂紋和應(yīng)力腐蝕裂紋。如制造時(shí)采用高強(qiáng)度鋼及對(duì)裂紋敏感的鋼材,在一定的使用條件下非常有可能產(chǎn)生裂紋,導(dǎo)致容器的失效。因此,在容器檢驗(yàn)前一定要認(rèn)真查閱制造、使用資料,弄清容器的材料、焊接工藝及使用情況后方可進(jìn)行磁粉檢測(cè)。

(二)檢測(cè)面的清理打磨應(yīng)符合要求

一般容器內(nèi)部與介質(zhì)接觸面大多有銹、氧化皮,有的還有防腐層,容器外部有漆,檢測(cè)時(shí)一定要對(duì)焊縫及兩側(cè)適當(dāng)寬度進(jìn)行認(rèn)真清理、打磨,以徹底去除覆蓋物,露出金屬光澤為合格,否則會(huì)掩蓋缺陷,影響缺陷顯示,造成漏檢。

(三)操作方法應(yīng)正確

在被探面上任意方向的裂紋都有與有效磁場(chǎng)最大幅值正交的機(jī)會(huì),從而得到最大限度的缺陷漏磁場(chǎng);相反,如果使交叉磁軛固定分段對(duì)焊縫探傷,就會(huì)使被探工件表面各點(diǎn)處于不同幅值和橢圓度的旋轉(zhuǎn)磁場(chǎng)作用下,結(jié)果將造成各點(diǎn)探傷靈敏度的不一致,對(duì)某些地方裂紋的探傷靈敏度降低。

(四)磁極端面與工件表面的間隙

磁極端面與工件表面之間保持一定間隙是為了交叉磁軛能在被探工件上移動(dòng)行走。如果間隙過(guò)大,將會(huì)在間隙處產(chǎn)生較大的漏磁場(chǎng)。

(五)交叉磁軛的磁化行走方向與磁懸液噴灑方向的配合為了避免磁懸液的流動(dòng)而沖刷掉缺陷上已經(jīng)形成的磁痕,并使磁粉有足夠的時(shí)間聚集到缺陷處。

參考文獻(xiàn)

第8篇:煙氣監(jiān)測(cè)范文

關(guān)鍵詞:企業(yè)融資成本;監(jiān)測(cè);貸款利率定價(jià);實(shí)證分析

中圖分類(lèi)號(hào):F832 文獻(xiàn)標(biāo)志碼:A 文章編號(hào):1673-291X(2017)03-0105-03

一、企業(yè)融資成本監(jiān)測(cè)的對(duì)象是企業(yè)綜合成本

為了確保融資成本概念界定的完整性以及兼顧分類(lèi)維度的可操作性、趨勢(shì)性分析的可行性,本文采用以企業(yè)為觀察端來(lái)界定融資成本,認(rèn)為融資成本是指企業(yè)在生產(chǎn)經(jīng)營(yíng)過(guò)程中為籌集資金所發(fā)生的一切費(fèi)用。即:

融資成本=融資費(fèi)用

而企業(yè)資產(chǎn)負(fù)債表中的“財(cái)務(wù)費(fèi)用”指,企業(yè)在生產(chǎn)經(jīng)營(yíng)過(guò)程中為籌集資金而發(fā)生的成本費(fèi)用。包括企業(yè)生產(chǎn)經(jīng)營(yíng)期間發(fā)生的利息支出、匯兌損益、擔(dān)保費(fèi)用、財(cái)產(chǎn)評(píng)估費(fèi)、保險(xiǎn)費(fèi)、公證費(fèi)等,較為準(zhǔn)確地反映了企業(yè)一定時(shí)期內(nèi)因融資(包括向銀行、非銀行單位和個(gè)人)而產(chǎn)生的費(fèi)用總支出。因此,融資成本的量化指標(biāo)選取企業(yè)資產(chǎn)負(fù)債表中的“財(cái)務(wù)費(fèi)用 ”。

二、基于金華轄內(nèi)384家小微企業(yè)貸款利率定價(jià)實(shí)證分析

(一)樣本企業(yè)的基本情況

從企業(yè)類(lèi)型來(lái)看,小型企業(yè)368家,占95.8%;微型企業(yè)16家,占4.2%;樣本涉及貸款余額36.79億元,合同期限平均11.4個(gè)月,平均執(zhí)行利率水平7.39%,平均上浮30.18%;從擔(dān)保方式來(lái)看,保證類(lèi)貸款約占40%,抵質(zhì)押類(lèi)貸款約占60%,暫無(wú)信用類(lèi)貸款;從企業(yè)性質(zhì)來(lái)看,95%的樣本企業(yè)為私人控股的民營(yíng)企業(yè),國(guó)有及集體企業(yè)、外商企業(yè)等合計(jì)占5%。樣本企業(yè)貸款筆數(shù)、金額地區(qū)分布。

(二)模型建立

結(jié)合實(shí)際情況,建立下列多元線性回歸模型:

Y=β0+β1X1+β2X2+…+β12X12+ε

其中,因變量為貸款利率(Y)(%);風(fēng)險(xiǎn)觀測(cè)指標(biāo)為逾期欠息天數(shù)(X1),這里取逾期或欠息或同時(shí)逾期欠息的最大天數(shù);企業(yè)財(cái)務(wù)指標(biāo)為資產(chǎn)負(fù)債率(X2)、流動(dòng)比率(X3)、銷(xiāo)售增長(zhǎng)率(X4)、應(yīng)收賬款周轉(zhuǎn)次數(shù)(X5)、盈利增長(zhǎng)率(X6)、上年末資產(chǎn)總額(X7)(萬(wàn)元)、上年?duì)I業(yè)收入(X8)(萬(wàn)元);企業(yè)融資情況指標(biāo)為貸款金額(X9)(萬(wàn)元)、貸款期限(X10)(月)、擔(dān)保方式(X11)(為虛擬變量);X12為企業(yè)年限(年);ε為隨機(jī)誤差項(xiàng),各指標(biāo)的均值、標(biāo)準(zhǔn)差(見(jiàn)表1)。

各指標(biāo)的相關(guān)性(如下頁(yè)表2所示)。

(三)實(shí)證結(jié)果

可以看出,部分變量之間的相關(guān)性較弱,因此,運(yùn)用SAS軟件進(jìn)行逐步回歸(四次),模型的輸出結(jié)果(見(jiàn)表3)。

為了檢驗(yàn)回歸方程的顯著性,即檢驗(yàn)原假設(shè)β1=β5=β6=

β11=0,我們計(jì)算出方差分析表(見(jiàn)表4)。

從表4中看出,P(F>F?鄣)

實(shí)證分析結(jié)果顯示,雖然轄內(nèi)小微企業(yè)貸款利率定價(jià)與風(fēng)險(xiǎn)有一定的正相關(guān)性,但風(fēng)險(xiǎn)定價(jià)的總體水平和能力較弱,貸款定價(jià)仍主要與擔(dān)保方式相關(guān),這意味著擔(dān)保方式目前仍然是影響小微企業(yè)貸款定價(jià)最關(guān)鍵的因素,小微企業(yè)貸款定價(jià)與企業(yè)的相關(guān)財(cái)務(wù)指標(biāo)呈現(xiàn)弱相關(guān)甚至不相關(guān)。主要原因?yàn)椋阂皇切∥⑵髽I(yè)自身財(cái)務(wù)制度不健全、財(cái)務(wù)管理不規(guī)范,很容易導(dǎo)致報(bào)表財(cái)務(wù)數(shù)據(jù)失真,影響模型的擬合效果;二是小微貸款的風(fēng)險(xiǎn)識(shí)別主要依靠軟信息,且定價(jià)受到最低定價(jià)政策等影響,較難真正實(shí)現(xiàn)基于風(fēng)險(xiǎn)水平的有效定價(jià)。

三、辯證看待融資成本問(wèn)題

第一,內(nèi)源融資比例低。內(nèi)源融資是企業(yè)利用自我儲(chǔ)蓄進(jìn)行投資,對(duì)企業(yè)資本的形成具有原始性、自主性、低成本性和風(fēng)險(xiǎn)小的特點(diǎn),是企業(yè)生存發(fā)展及融資的立足之本。但是現(xiàn)階段,大部分企業(yè)特別是小微企業(yè)的自有資金仍然較少,在需要擴(kuò)大生產(chǎn)規(guī)模,增加投入,進(jìn)行轉(zhuǎn)型升級(jí)的過(guò)程中,往往需要依靠外源融資,導(dǎo)致企業(yè)資產(chǎn)負(fù)債率偏高。而企業(yè)實(shí)際融資成本高與企業(yè)資產(chǎn)負(fù)債率過(guò)高有關(guān),2015年12月末,金華市規(guī)模以上工業(yè)企業(yè)資產(chǎn)負(fù)債率為60.99%,資產(chǎn)負(fù)債率偏高,融資成本相應(yīng)也會(huì)有所提高。

第二,過(guò)多依賴(lài)間接融資。外源融資又可分為直接融資和間接融資,而直接融資又可分為股票融資和債券融Y等。在經(jīng)濟(jì)日益市場(chǎng)化、信用化和證券化的過(guò)程中,外源融資成為企業(yè)獲取資金的主要方式。我國(guó)的股票市場(chǎng)和債券市場(chǎng)從無(wú)到有,已經(jīng)有了很大的發(fā)展。但總體上看,資本市場(chǎng)仍不發(fā)達(dá),且結(jié)構(gòu)不合理,大部分企業(yè)的資金來(lái)源也仍舊以銀行為主。

第三,短貸長(zhǎng)用推升成本。2015年12月末,全市小微企業(yè)貸款占全部企業(yè)貸款比重為52.08%,在與銀行的談判過(guò)程中,小微企業(yè)議價(jià)能力較弱,融資成本相應(yīng)較高,貸款期限也相對(duì)較短,金華市企業(yè)貸款短期占比較高,2015年12月末占比為77.59%。短貸長(zhǎng)用現(xiàn)象突出,續(xù)貸期會(huì)衍生出一系列相關(guān)費(fèi)用,從而從總體上推高企業(yè)實(shí)際融資成本。

第四,企業(yè)風(fēng)險(xiǎn)影響貸款定價(jià)。由于小微企業(yè)具有數(shù)量多、情況雜、行業(yè)分布廣、生命周期短的特點(diǎn),受政策及市場(chǎng)波動(dòng)的影響較大,且缺乏足額有效的抵質(zhì)押擔(dān)保物,抗風(fēng)險(xiǎn)能力較弱,使得商業(yè)銀行在提供信貸資金時(shí)較為審慎,或通過(guò)嚴(yán)格抵押擔(dān)保,或通過(guò)縮短貸款期限,或通過(guò)提高貸款利率等方式,加強(qiáng)信貸風(fēng)險(xiǎn)控制,相應(yīng)降低了銀企雙方的貸款意愿,使得在較多的市場(chǎng)資金供給下,小微企業(yè)融資難現(xiàn)象仍沒(méi)有得到根本解決。

第五,企業(yè)效益不理想。融資費(fèi)用占利潤(rùn)比重較高與企業(yè)感覺(jué)融資難密切相關(guān)。自去年年底央行連續(xù)降準(zhǔn)降息后,規(guī)模以上企業(yè)融資成本有所下降,2015年,金華全市規(guī)模以上工業(yè)企業(yè)財(cái)務(wù)費(fèi)用占利潤(rùn)總額的比重為41.6%,較去年下降4.8個(gè)百分點(diǎn),但仍接近利潤(rùn)總額的四成。因此,當(dāng)前企業(yè)融資難感受強(qiáng)烈的主要原因是融資成本的相對(duì)水平高,即企業(yè)融資成本占利潤(rùn)總額比重較高。進(jìn)一步分析可知,金華市企業(yè)融資成本相對(duì)水平高,主要與該市企業(yè)財(cái)務(wù)杠桿過(guò)高和經(jīng)營(yíng)效益下滑有關(guān)。2015年,全市規(guī)模以上工業(yè)企業(yè)虧損額增長(zhǎng)35.5%,比去年同期上升11.6個(gè)百分點(diǎn)。

參考文獻(xiàn):

[1] 呂東鍇,蔣先玲.我國(guó)中小企業(yè)債務(wù)融資現(xiàn)狀及其成因探討[J].求實(shí),2012,(2).

[2] 王宏.扶持中小企業(yè)債務(wù)融資的經(jīng)驗(yàn)借鑒與政策建議[J].陜西廣播電視大學(xué)學(xué)報(bào),2011,(4).

[3] 陳建林.家族控制與民營(yíng)企業(yè)債務(wù)融資:促進(jìn)效應(yīng)還是阻礙效應(yīng)[J].財(cái)經(jīng)研究,2013,(7).

[4] 袁梅.基于信用擔(dān)保的林業(yè)企業(yè)債務(wù)融資問(wèn)題與對(duì)策探析[J].林業(yè)經(jīng)濟(jì),2013,(6).

第9篇:煙氣監(jiān)測(cè)范文

關(guān)鍵詞:發(fā)動(dòng)機(jī);機(jī)油濾清器;檢測(cè)

發(fā)動(dòng)機(jī)內(nèi)各個(gè)零部件是經(jīng)過(guò)機(jī)油的來(lái)實(shí)現(xiàn)正常工作的,但是零部件運(yùn)轉(zhuǎn)時(shí)所產(chǎn)生的金屬碎屑、進(jìn)入的塵土、高溫下被氧化的積碳以及部分水汽會(huì)不斷的混入機(jī)油中,時(shí)間長(zhǎng)了機(jī)油的使用壽命會(huì)被減少,嚴(yán)重時(shí)有可能影響發(fā)動(dòng)機(jī)正常運(yùn)轉(zhuǎn)。因此,這個(gè)時(shí)候機(jī)油濾清器的作用就體現(xiàn)出來(lái)了。簡(jiǎn)單的說(shuō),機(jī)油濾清器的作用主要是過(guò)濾機(jī)油中絕大部分雜質(zhì),保待機(jī)油的清潔,延長(zhǎng)其正常使用壽命。另外,機(jī)油濾清器還應(yīng)該具有過(guò)濾能力強(qiáng)、流通阻力小、使用壽命長(zhǎng)等性能。

1.機(jī)油濾清器工作機(jī)理

機(jī)油濾清器的工作原理一般按雜質(zhì)過(guò)濾方法分為三種:機(jī)械分離、離心分離和磁性吸附。機(jī)械分離按其作用形式又可分為純機(jī)械分離、架空分離和吸附分離等三種,純機(jī)械分離常見(jiàn)的有濾網(wǎng)過(guò)濾,即以一定孔徑濾材過(guò)濾機(jī)械雜質(zhì)和油泥,粒徑大于濾孔的雜質(zhì)被濾材阻攔而過(guò)濾掉。架空分離是指有 n個(gè)小粒子附著于濾孔內(nèi)壁上,粒子并逐漸增多,使濾孔逐漸變小,形成架空現(xiàn)象,使過(guò)濾出來(lái)的粒子尺寸小于濾孔尺寸。由于機(jī)油中粒子形狀多數(shù)是不規(guī)則的,所以架空現(xiàn)象易于形成。另外對(duì)于機(jī)油中的膠性物質(zhì),常粘附在濾材表面或?yàn)V孔內(nèi)壁形成吸附。而真實(shí)的過(guò)濾情況,一般來(lái)說(shuō)不是單一原理的作用,而可能是上述幾種的組合。離心分離指機(jī)油通過(guò)一個(gè)高速旋轉(zhuǎn)的轉(zhuǎn)子,使油中雜質(zhì)受離心力作用被甩向轉(zhuǎn)子內(nèi)壁,從而從機(jī)油中分離出來(lái)。磁性吸附是利用永久磁鐵的磁性力將機(jī)油中的鐵質(zhì)粒子吸附,不讓它們?cè)跈C(jī)油系統(tǒng)中來(lái)回循環(huán),危害發(fā)動(dòng)機(jī)零部件。

2.濾清器的濾芯種類(lèi)分析

2.1微孔濾紙濾芯

用某種樹(shù)脂浸漬過(guò)的特殊濾紙,經(jīng)熱固化處理后挺度和強(qiáng)度都大大提高,能經(jīng)受一定壓力的作用。由于純粹的紙濾芯在使用過(guò)程中容易被油壓擠壓收縮,縮短使用壽命。為了克服這一缺點(diǎn),在濾芯內(nèi)壁加襯網(wǎng)或襯骨架,而且在濾紙表面軋出波形瓦楞,極大提高濾芯使用壽命?,F(xiàn)在的濾清器濾芯一般是一次性的,堵塞后更換新的芯子。紙濾芯通常按裝在主油道中作全流過(guò)濾,但也可以按裝在并聯(lián)于主油道的分流支路上作分流過(guò)濾。

2.2塑料濾芯

采用一定粘度耐熱耐腐蝕的工程塑料,經(jīng)模壓燒結(jié)成為多孔性具有深度過(guò)濾作用的濾芯。這種濾芯可以按一定堆積保養(yǎng)后繼續(xù)使用。金屬網(wǎng)濾芯,用每英寸 100~200目的磷銅絲網(wǎng)或黃銅絲網(wǎng)作濾芯材料,濾芯形狀有圓筒形和疊片形。金屬網(wǎng)濾芯流量大,阻力小,作用可靠,易于清洗,常用作全流過(guò)濾。過(guò)濾細(xì)度視網(wǎng)孔規(guī)格而定。近年來(lái)由于化學(xué)工業(yè)的發(fā)展,現(xiàn)在已有用尼龍材料作支承濾網(wǎng)的骨架,用尼龍布代替金屬網(wǎng),這樣的結(jié)構(gòu),節(jié)省了有色金屬,有利于生產(chǎn)發(fā)展。繞線式濾芯,用鋼帶或黃銅帶軋成,表面上每隔一定距離有一凸起的形狀,凸起的高度 004~009毫米,把這種金屬帶繞在一個(gè)表面有溝槽的波紋筒上,上一條帶的底面和下一條帶的凸起面相接觸,形成了許多間隙,這就是繞線縫隙式濾芯。

2.3離心式濾清器

利用系統(tǒng)本身的壓力能,由通過(guò)噴咀的油產(chǎn)生一個(gè)反作用力矩,驅(qū)動(dòng)轉(zhuǎn)子轉(zhuǎn)動(dòng),轉(zhuǎn)子內(nèi)的油在離心力作用下,分離出固態(tài)雜質(zhì),積聚在轉(zhuǎn)子內(nèi)壁上,轉(zhuǎn)子中心部份的油變得清潔,從噴咀流回油底殼。這便是離心式濾清器的作用原理,若將轉(zhuǎn)子中心部分的油直接引入主油道,就成為全流離心式濾清器,而把前述的結(jié)構(gòu)稱(chēng)為分流離心式濾清器。

3.濾清器的性能指標(biāo)與檢測(cè)

3.1流量阻力特性

在額定的流量下濾清器前后產(chǎn)生的壓差,也是壓力損失值,它的數(shù)值越小表示濾清器通過(guò)性越好。額定流量一般這樣?。喝绻脩?hù)提供機(jī)油泵設(shè)計(jì)流量或新機(jī)油泵實(shí)測(cè)流量,則濾清器流量可取機(jī)油泵流量值的 50~60%;也有用戶(hù)向?yàn)V清器設(shè)計(jì)者提供內(nèi)燃機(jī)主油道的設(shè)計(jì)流量。在這種情況下,濾清器的流量值應(yīng)定在主油道設(shè)計(jì)流量的 1.5~2.0倍。這是因?yàn)殡S著內(nèi)燃機(jī)能的正常磨損,主油道流量會(huì)相應(yīng)增大以維持正常機(jī)油壓力。一般要求全流式濾清器在通過(guò)額定流量時(shí)的原始阻力不應(yīng)大于0.025MPa。

3.2新濾芯測(cè)定的過(guò)濾效率

我們定義對(duì)新濾芯測(cè)定的過(guò)濾效率,稱(chēng)為原始過(guò)濾效率,要求≥60%(在使用中由于濾芯表面上逐漸堆積起來(lái)雜質(zhì)層,過(guò)濾效率愈來(lái)愈高。所以,濾芯在整個(gè)使用壽命期內(nèi)的累積平均效率要大于原始效率,一般在70%~80%)。測(cè)定原始濾清效率時(shí),把含有一定數(shù)量一定尺寸AC 灰的油料,以10%左右額定流量或大于45kPa 壓力下一次性通過(guò)濾清器,并多次沖洗后,分析過(guò)濾后油料中雜質(zhì)含量,便可計(jì)算出原始過(guò)濾效率,不同粒徑AC 灰得出的結(jié)果不同。

3.3壽命特性

一個(gè)新濾芯從開(kāi)始使用到堵塞,即濾芯前后壓力差達(dá)到濾清器旁通閥開(kāi)啟壓力的70%(一般開(kāi)啟壓力為100kPa±20 kPa)。在堵塞壽命試驗(yàn)臺(tái)上測(cè)定濾清器壽命時(shí),需在試驗(yàn)油中勻速加入試驗(yàn)雜質(zhì),倍速地模擬濾芯實(shí)際使用條件下堵塞。在試驗(yàn)過(guò)程中,每隔20 或30min記錄濾清器前后壓力差,當(dāng)壓力差達(dá)到70 kPa 時(shí),試驗(yàn)終止,到這時(shí)為止的小時(shí)數(shù)(壽命時(shí)間)或已加入的試驗(yàn)雜質(zhì)總量(容灰量),即作為評(píng)價(jià)濾清器壽命的指標(biāo),在壽命試驗(yàn)過(guò)程中,還可以定時(shí)測(cè)定濾清器的濾清效率,稱(chēng)為累積濾清效率,代表濾清器在堵塞過(guò)程中過(guò)濾效率的變化。累計(jì)效率比原始效率更全面地反映濾芯性能。

4.結(jié)束語(yǔ)

理想的機(jī)油濾清器應(yīng)該是匹配流量下,阻力小,過(guò)濾效率高,壽命長(zhǎng),而實(shí)際上各個(gè)指標(biāo)是互相制約的,如流量越大時(shí)阻力便越大,過(guò)濾效率越高說(shuō)明濾芯孔隙越小阻力越大,而使用壽命減短等缺點(diǎn)。

參考文獻(xiàn):